KWS Manufacturing

Slide Gate Design Standards

KWS Pneumatic Slide Gate Standard Construction

KWS standard pneumatic slide gate cylinders operate most effectively when supplied with 80 psi of clean and dry air. The standard design slide gates are not designed to be operated under a head load; however, hopper/silo discharge slide gates can be engineered to meet your specific application.

Please contact the KWS sales and engineering staff with any of your unique slide gate applications today. We can provide a solution for you!

Gate Size Inside Square Dimension Body Thickness Blade Thickness Cylinder Bore
6" 7" 10 GA   3/16" 2"
9" 10" 10 GA   3/16" 2"
10" 11" 10 GA   3/16" 2"
12" 13"   3/16"   1/4" 2"
14" 15"   3/16"   1/4" 2"
16" 17"   3/16"   3/8" 2 ½"
18" 19"   3/16" 3/8" 2 ½"
20" 21"   3/16"   3/8" 2 ½"
24" 25"   3/16"   3/8" 2 ½"
30" 31"   1/4"   3/8" 4"
36" 37"   1/4"   1/2" 4"

Get Connected

CEMA Standard Components and Complete Engineered Systems

Contact Us Online Resources
KWS Mfg Captain Conveyor

Ask CaptAIn Conveyor An AI Powered Bulk Material Handling Expert

CaptAIn Conveyor AI Chat